NEXT
User name paschke
Log entry time 18:46:16 on October25,2005
Entry number 158003
keyword=Default Pedestals changed after run 5889
I modified the default pedestal files for the Counting House crate and the Left
spectrometer crate, in order to apply newly calibrated pedestals for bpms 8, 10
12, 4a, 4b, bcmcav2, bcmcav3, bcm1, bcm2, and bcm3. This change will take
effect starting with the next run:
Run 5890.
I have not yet applied these changes to previous runs, but this should probably
be done sometime, along with a re-analysis of that data. The pedestals used
are listed below, in a format suitable for inclusion in a pedestal template
file.
bcm1r 4348.0
bcm2r 4490.0
bcm3r 4629.4
bcmcav2r 24645.4
bcmcav3r 24876.1
bpm4axp 8471.0
bpm4axm 8822.3
bpm4ayp 7579.5
bpm4aym 8051.7
bpm4bxp 7679.3
bpm4bxm 8275.8
bpm4byp 6978.4
bpm4bym 7164.8
bpm8xp 6711.9
bpm8xm 6857.2
bpm8yp 0.06418
bpm8ym 0.06538
bpm10xp 6605.3
bpm10xm 6542.7
bpm10yp 7167.0
bpm10ym 7513.3
bpm12xp 7875.4
bpm12xm 7553.7
bpm12yp 7925.0
bpm12ym 8151.2