User name J. Singh
Log entry time 07:00:17 on October27,2005
Entry number 158140
keyword=Left and Right HRS and Septum Magnet SET Points
if a single magnet trips off, then the correct SET point can
be found in the following table.
Left and Right HRS and Septum Magnet SET points
(as of 0655 10/27/05)
Left Right
momentum 3.12340 GeV/c 3.11260 GeV/c
Q1 1875.49730 A 1859.12965 A
Q2 1355.40 A 1350.71 A
Dipole 1098.88257 A 1118.53308 A
Q3 1462.66 A 1457.60 A
Septum 323.61 A 316.92 A
the right dipole set point was fluctuating in the last
four digits, so like whatever. all other values were
stable.