User name J. Singh
Log entry time 08:03:46 on October27,2005
Entry number 158150
keyword=recovering from right septum trip
the lower coil is at 6.64K, the yoke is at 5.02K, and the upper coil is at 7.54K. since we are below 7.8K, we will start the recovery procedure.
(1) turned off dump switch and power supply
(2) reset interlocks, after a few secs, the interlocks cleared
(3) turned on dump switch, after a few secs, the indicator turned green
(4) turing on power supply, after a few secs, indicators turned green
(5) set current to 316.92 A, after a few seconds, the current started to ramp up at 0.2 A/sec
current on its way back up!
FIGURE 1