    User name paschke

    Log entry time 07:26:52 on November 4,2005

    Entry number 159068

    This entry is a followup to: 158926

    Followups:

    keyword=Background Study: Left arm P0 scan

    
    Background Studies.  This is a reprise of last night: halag 158926.
    
    Turned Dithering off.
    All taken at 56-57 uA.... forgot to lower to 50uA to match yesterday... 
    
    This is all good Right Arm production.
    
    Run Summary:
        6137-6146.     RIGHT ARM PRODUCTION. LEFT ARM CHANGING, NOT TO BE USED.
        6147-6148.     JUNK
        6149...        BACK TO PRODUCTION
    
    
    I'll post results soon but for now, just the summary table.
    
    
    dP |     L-D1        |   L-Sep     Run  |                   Det 1               
      |                 Det 2                 |    BCM1      
       | Mom      Cur    |    Cur           |   HV    Signal  (Norm)   Width    Wt. 
      |   HV   Signal (Norm)   Width    Wt.   |    Avg
    --------------------------------------------------------------------------------
    ---------------------------------------------------
    
    10  3.1334  1103.74     324.6     6137                                          
         -1391             <<< Momentum Settling before Clean >>>
                                             -1761   ~48500    2.82
                                             -1491    ~5850    0.343         << 
    Careful: I accidentally moved momentum setting before not-clean>>
    
    20  3.1434  1107.75     325.68    6138   -1761    ~3500    0.203                
                                     << Clean for Signal Check >> 
                                             -2050   ~24000    1.39
                                      6139   -2050   ~24000    1.39    11210   
    0.010            ~41000  2.40     869.1   0.990     17190
    
    25  3.1484  1109.75     326.20    6140   -2050   ~19000                         
                ~35000       << Momentum settling before clean >>
                                      6141           ~19000    1.10    13930   
    0.008                    2.03     919.5   0.992     17180
    
    30  3.1534  1111.75     326.7     6142   -2050   ~16000                         
         -1391  ~26000       << Momentum settling before clean >>
                                             -2050                                  
         -1460  ~48000
                                      6143   -2050   ~16000    0.936   15660   
    0.013     -1460  ~48000  2.78     1060    0.987     17190
    
    15  3.1384  1105.74     325.2     6144   -1751    ~8600                         
         -1361  ~46500       << Momentum settling before clean >>
                                             -1951   ~33500
                                      6145   -1951                                  
                               << Septum Mis-set (left at +30) >>
    				  6146   -1951   ~33500    1.961    6596        
                        2.66      826.3            17180
                                      6147   -1761    ~9200                         
              << used matching HV this time... Short run, junk >>
    
                                      6148                                 << while 
    returning left HRS to nominal settings... short run, junk. >>
     0  3.1234  1099.74     323.61           -1491                                  
          -1391                          << back to production >>
        -- Turned dithering back on
        -- Started Run 6149
    
      ** Altogether, this took about 2.5 hours, but the right arm data is good for 
    production. **