User name a-onl
Log entry time 19:22:07 on November 4, 2005
Entry number 159118
keyword=End_of_Run_2986
****************************
Run Number: 2986
End of Run Comment:
Run_type=other,beam_energy=3.178,beam_raster=on,comment_text=cavity check,daq_mode=twoarm,kin_name=,leftarm_p=3.1334,leftarm_theta=6.0,rightarm_p=3.1226,rightarm_theta=6.0,target_type=LH2
PRESCALE FACTORS:ps1=1645 ps2=1300 ps3=1520 ps4=160 ps5=10 ps6=10 ps7=1 ps8=1
EVENTS[0]: 58278 [+]: 57401 [-]: 0
TIME [0]: 16.574 mins [+]: 16.396 mins [-]: 0.017 mins
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/0.0 Hz T2[0] : 0.0/0.0 Hz T3[0] : 0.0/0.0 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] :58.6/58.6 Hz T8[0] :58.6/58.6 Hz
T1[+] : 0.0/0.0 Hz T2[+] : 0.0/0.0 Hz T3[+] : 0.0/0.0 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] :58.6/58.6 Hz T8[+] :58.6/58.6 Hz
T1[-] : 0.0/0.0 Hz T2[-] : 0.0/0.0 Hz T3[-] : 0.0/0.0 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/22 T2[0] : 0/0 T3[0] : 0/0 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 58310/58310 T8[0] : 58275/58275
T1[+] : 0/22 T2[+] : 0/0 T3[+] : 0/0 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 57682/57682 T8[+] : 57647/57647
T1[-] : 0/0 T2[-] : 0/0 T3[-] : 0/0 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 0/0
AVERAGE CURRENT
BCM x1 : 46.4742uA BCM x3 : 46.3557uA BCM x10: 45.6155uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.005E+06 ppm BCM u3 :1.002E+06 ppm BCM u10:1.001E+06 ppm
BCM d1 :1.001E+06 ppm BCM d3 :1.001E+06 ppm BCM d10:1.001E+06 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.04612 BCM u3 [0]:0.046 BCM u10[0]:0.04602
BCM u1 [+]:0.04567 BCM u3 [+]:0.04555 BCM u10[+]:0.04556
BCM u1 [-]:-1.149E-07 BCM u3 [-]:-4.003E-08 BCM u10[-]:-2.898E-08
BCM d1 [0]:0.04631 BCM d3 [0]:0.04619 BCM d10[0]:0.04471
BCM d1 [+]:0.04585 BCM d3 [+]:0.04573 BCM d10[+]:0.04426
BCM d1 [-]:-2.559E-08 BCM d3 [-]:-2.627E-08 BCM d10[-]:-2.334E-08
****************************
End-of-run EPICS data for Run Number 2986 at Fri Nov 4 19:22:03 EST 2005
Left Arm D1 momentum : 3.1234
Left Arm arm angle : 12.321
Right Arm D1 momentum : 3.1126
Right Arm arm angle : 0
HALLA:p : 3181.23
HALLA:dpp : -0.000110388
Tiefenbach Hall A energy : 3181.23
Right Arm arm mispointing (HPT) : 0
Left Arm Top VDC Current : 0.78125
Left Arm Bottom VDC Current : 0.830078
Left septum set current : 323.61
Left septum current readback : 316.772
Left septum upper coil T : 6.624
Left septum lower coil T : 6.725
Right septum set current : 316.92
Right septum current readback : 311.523
Right septum upper coil T : 7.252
Right septum lower coil T : 6.868
Left Arm Q1 momentum : 3.12338
Left Arm Q2 power supply current : 1355.2
Left Arm Q2 momentum : 3.12294
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1098.86
Left Arm D1 momentum : 3.1234
Left Arm D1 NMR : 1.15663
Left Arm Q3 power supply current : 1462.8
Left Arm Q3 momentum : 3.1237
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 3.11261
Right Arm Q1 gauss meter : -0.04636
Right Arm Q2 power supply current : 1350.72
Right Arm Q2 momentum : 3.11262
Right Arm Q2 gauss meter : 0.7088
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1123.17
Right Arm D1 momentum : 3.1126
Right Arm D1 NMR : 1.15505
Right Arm Q3 power supply current : 1457.71
Right Arm Q3 momentum : 3.11284
Right Arm Q3 gauss meter : 0.654
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 56.3984
Current on Unser monitor : 52.046
Current on Upstream bcm : 55.816
Current on Downstream bcm : 56.9808
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 56.8135
Hall C Current : 0.12947
MBSY1c Hall A Beam energy : 3186.44
MBSY1c magnet current (amp) : 132.682
MBSY1c Bdl : 795181
MBSY3c Hall C Beam energy : 1101.35
Tiefenbach Hall A energy : 3181.23
Tiefenbach Hall C energy : 20.6623
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.000297487
IPM1H04A.XPOS : 1.56637
IPM1H04A.YPOS : -0.0704002
IPM1H04B.XPOS : -1.412
IPM1H04B.YPOS : 0.00165987
Left Arm Collimator : 0.0572754
HacL_HPE1313A:0_Ch58 : -0.205566
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : 0.0170898