Log entry time 22:42:46 on November 6, 2005
Entry number 159331
keyword=End_of_Run_2996
****************************
Run Number: 2996
End of Run Comment:
Run_type=spot++,beam_energy=3.178,beam_raster=on,comment_text=raster check,daq_mode=twoarm,kin_name=,leftarm_p=3.1334,leftarm_theta=6.0,rightarm_p=3.1226,rightarm_theta=6.0,target_type=LH2
PRESCALE FACTORS:ps1=1645 ps2=1300 ps3=1520 ps4=160 ps5=10 ps6=10 ps7=1 ps8=1
EVENTS[0]: 10004 [+]: 9857 [-]: 0
TIME [0]: 2.844 mins [+]: 2.869 mins [-]: 0.017 mins
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/0.3 Hz T2[0] : 0.0/0.0 Hz T3[0] : 0.0/0.0 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] :58.9/58.9 Hz T8[0] :58.6/58.6 Hz
T1[+] : 0.0/0.3 Hz T2[+] : 0.0/0.0 Hz T3[+] : 0.0/0.0 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] :58.9/58.9 Hz T8[+] :58.6/58.6 Hz
T1[-] : 0.0/0.0 Hz T2[-] : 0.0/0.0 Hz T3[-] : 0.0/0.0 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/57 T2[0] : 0/0 T3[0] : 0/0 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 10057/10057 T8[0] : 10000/10000
T1[+] : 0/57 T2[+] : 0/0 T3[+] : 0/0 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 10147/10147 T8[+] : 10090/10090
T1[-] : 0/0 T2[-] : 0/0 T3[-] : 0/0 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 0/0
AVERAGE CURRENT
BCM x1 : 57.4358uA BCM x3 : 57.3116uA BCM x10: 56.0167uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.004E+06 ppm BCM u3 :1.001E+06 ppm BCM u10:1.001E+06 ppm
BCM d1 :1.001E+06 ppm BCM d3 :1.001E+06 ppm BCM d10:1.001E+06 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.00984 BCM u3 [0]:0.009818 BCM u10[0]:0.009745
BCM u1 [+]:0.009924 BCM u3 [+]:0.009902 BCM u10[+]:0.009829
BCM u1 [-]:-1.149E-07 BCM u3 [-]:-4.003E-08 BCM u10[-]:-2.898E-08
BCM d1 [0]:0.009764 BCM d3 [0]:0.009744 BCM d10[0]:0.009374
BCM d1 [+]:0.009848 BCM d3 [+]:0.009827 BCM d10[+]:0.009455
BCM d1 [-]:-2.559E-08 BCM d3 [-]:-2.627E-08 BCM d10[-]:-2.334E-08
****************************
End-of-run EPICS data for Run Number 2996 at Sun Nov 6 22:42:44 EST 2005
Left Arm D1 momentum : 3.12339
Left Arm arm angle : 0
Right Arm D1 momentum : 3.1126
Right Arm arm angle : 0
HALLA:p : 3181.23
HALLA:dpp : -0.000112604
Tiefenbach Hall A energy : 3181.23
Right Arm arm mispointing (HPT) : 0
Left Arm Top VDC Current : 0.830078
Left Arm Bottom VDC Current : 0.878906
Left septum set current : 323.61
Left septum current readback : 316.895
Left septum upper coil T : 6.435
Left septum lower coil T : 6.513
Right septum set current : 316.919
Right septum current readback : 311.768
Right septum upper coil T : 6.978
Right septum lower coil T : 6.587
Left Arm Q1 momentum : 3.12338
Left Arm Q2 power supply current : 1355.5
Left Arm Q2 momentum : 3.12363
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1097.9
Left Arm D1 momentum : 3.12339
Left Arm D1 NMR : 1.15662
Left Arm Q3 power supply current : 1462.58
Left Arm Q3 momentum : 3.12323
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 3.11252
Right Arm Q1 gauss meter : -0.04633
Right Arm Q2 power supply current : 1350.76
Right Arm Q2 momentum : 3.1127
Right Arm Q2 gauss meter : 0.7088
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1123.18
Right Arm D1 momentum : 3.1126
Right Arm D1 NMR : 1.15505
Right Arm Q3 power supply current : 1457.48
Right Arm Q3 momentum : 3.11235
Right Arm Q3 gauss meter : 0.654
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 57.5131
Current on Unser monitor : 52.9466
Current on Upstream bcm : 57.0865
Current on Downstream bcm : 57.9398
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 57.7168
Hall C Current : 0.126771
MBSY1c Hall A Beam energy : 3186.44
MBSY1c magnet current (amp) : 132.682
MBSY1c Bdl : 795181
MBSY3c Hall C Beam energy : 1101.35
Tiefenbach Hall A energy : 3181.22
Tiefenbach Hall C energy : nan
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : -0.00255945
IPM1H04A.XPOS : 1.66111
IPM1H04A.YPOS : -0.56899
IPM1H04B.XPOS : -1.22284
IPM1H04B.YPOS : -0.687639
Left Arm Collimator : 0.0570801
HacL_HPE1313A:0_Ch58 : -0.20752
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : 0.0161133