User name a-onl
Log entry time 23:48:52 on November 14, 2005
Entry number 160219
keyword=End_of_Run_3070
****************************
Run Number: 3070
End of Run Comment:
Run_type=spot++,beam_energy=3.178,beam_raster=on,comment_text=raster - Long run (1 hour or more), as requested by RC,daq_mode=twoarm,kin_name=,leftarm_p=3.1234,leftarm_theta=6.0,rightarm_p=3.1126,rightarm_theta=6.0,target_type=LH2
PRESCALE FACTORS:ps1=1645 ps2=1300 ps3=1520 ps4=160 ps5=10 ps6=10 ps7=1 ps8=1
EVENTS[0]: 10001 [+]: 9848 [-]: 0
TIME [0]: 2.844 mins [+]: 2.865 mins [-]: 0.017 mins
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/0.0 Hz T2[0] : 0.0/0.0 Hz T3[0] : 0.0/0.0 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] :58.6/58.6 Hz T8[0] :58.6/58.6 Hz
T1[+] : 0.0/0.0 Hz T2[+] : 0.0/0.0 Hz T3[+] : 0.0/0.0 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] :58.6/58.6 Hz T8[+] :58.6/58.6 Hz
T1[-] : 0.0/0.0 Hz T2[-] : 0.0/0.0 Hz T3[-] : 0.0/0.0 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/0 T2[0] : 0/0 T3[0] : 0/0 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 10001/10001 T8[0] : 10001/10001
T1[+] : 0/0 T2[+] : 0/0 T3[+] : 0/0 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 10072/10072 T8[+] : 10072/10072
T1[-] : 0/0 T2[-] : 0/0 T3[-] : 0/0 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 0/0
AVERAGE CURRENT
BCM x1 : 46.8874uA BCM x3 : 46.7635uA BCM x10: 45.8472uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.005E+06 ppm BCM u3 :1.002E+06 ppm BCM u10:1.001E+06 ppm
BCM d1 :1.001E+06 ppm BCM d3 :1.001E+06 ppm BCM d10:1.001E+06 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.008039 BCM u3 [0]:0.008017 BCM u10[0]:0.007964
BCM u1 [+]:0.008139 BCM u3 [+]:0.008117 BCM u10[+]:0.008063
BCM u1 [-]:-1.149E-07 BCM u3 [-]:-4.003E-08 BCM u10[-]:-2.898E-08
BCM d1 [0]:0.007965 BCM d3 [0]:0.007944 BCM d10[0]:0.007685
BCM d1 [+]:0.008064 BCM d3 [+]:0.008043 BCM d10[+]:0.00778
BCM d1 [-]:-2.559E-08 BCM d3 [-]:-2.627E-08 BCM d10[-]:-2.334E-08
****************************
End-of-run EPICS data for Run Number 3070 at Mon Nov 14 23:48:50 EST 2005
Left Arm D1 momentum : 3.12341
Left Arm arm angle : 0
Right Arm D1 momentum : 3.11259
Right Arm arm angle : 0
HALLA:p : 3181.22
HALLA:dpp : -0.00011398
Tiefenbach Hall A energy : 3181.22
Right Arm arm mispointing (HPT) : 0
Left Arm Top VDC Current : 0.878906
Left Arm Bottom VDC Current : 0.878906
Left septum set current : 323.61
Left septum current readback : 316.895
Left septum upper coil T : 6.702
Left septum lower coil T : 6.859
Right septum set current : 316.92
Right septum current readback : 310.791
Right septum upper coil T : 7.286
Right septum lower coil T : 6.926
Left Arm Q1 momentum : 3.12321
Left Arm Q2 power supply current : 1355.41
Left Arm Q2 momentum : 3.12342
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1099.16
Left Arm D1 momentum : 3.12341
Left Arm D1 NMR : 1.15663
Left Arm Q3 power supply current : 1462.52
Left Arm Q3 momentum : 3.12311
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 3.11252
Right Arm Q1 gauss meter : -0.04628
Right Arm Q2 power supply current : 1350.66
Right Arm Q2 momentum : 3.11249
Right Arm Q2 gauss meter : 0.7085
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1123.47
Right Arm D1 momentum : 3.11259
Right Arm D1 NMR : 1.15505
Right Arm Q3 power supply current : 1457.51
Right Arm Q3 momentum : 3.11241
Right Arm Q3 gauss meter : 0.6539
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 57.694
Current on Unser monitor : 53.8388
Current on Upstream bcm : 56.9962
Current on Downstream bcm : 58.3918
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 58.4463
Hall C Current : 0.129666
MBSY1c Hall A Beam energy : 3186.44
MBSY1c magnet current (amp) : 132.682
MBSY1c Bdl : 795181
MBSY3c Hall C Beam energy : 1101.35
Tiefenbach Hall A energy : 3181.22
Tiefenbach Hall C energy : nan
Delta(E)/E width (MV_AI_DXWID) : 0.448828
IPM1C12.XPOS : -0.0012939
IPM1H04A.XPOS : 1.55811
IPM1H04A.YPOS : 0.0614407
IPM1H04B.XPOS : -1.40192
IPM1H04B.YPOS : 0.31056
Left Arm Collimator : 0.0572754
HacL_HPE1313A:0_Ch58 : -0.20752
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : 0.0136719