• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name paschke

    Log entry time 18:06:26 on November16,2005

    Entry number 160378

    This entry is a followup to: 160320

    keyword=89% inj transmission, Large Aq width

    
    The problem Bryan noted last night (poor injector transmission and large charge 
    asymmetry width) is recurring tonight.  I complained to MCC, with the caveat 
    that they shouldn't interrupt beam delivery to fix it... but if it is easy, 
    just tweak it up.  They seemed to understand that we care, but not so much we'd 
    rather not take beam...
    
    By the way, MCC induced a beam trip to check our transmission with A beam only. 
     The answer, ~89%, was within a couple of percent of what is measured when B is 
    on.
    
    Tomorrow we should have an injector expert (Reza?) take a look at this.  There 
    are two possible problems: 1) creation of beam position differences due to 
    clipping and 2) creation of beam position differences due to large PITA 
    feedback trying to counteract effects from helicity correlated transmission.   
    But right now, position differences don't look particularly bad and the PITA 
    feedback values are still reasonable.