Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 07:58:53 on November 17, 2005
Entry number 160430
This entry is a followup to: 160419
keyword=TS1 resets
The problem with TS1 reboots is well known, at least in some circles. Try rebooting it
from the "crate resets" button available in the main "Hall A Tools GUI" on the controls
computer. This is also explained in the spectrometer DAQ web page linked from the
Hall A web page. Anyway, the following will reboot TS1 with their corresponding approx.
rate of success:
1. Type "reboot" at vxWorks -- 80 %
2. Type "ctrl-X" at vxWorks -- 90%
3. Use reset GUI as explained above -- 98 %
4. Take access and push reset button on the cpu -- 99 %
5. Power cycle the VME crate (sometimes necessary) -- virtually 100 %, unless the power
supply is busted (which has happened too).
This halog entry is accessible via google !
Oh, and my pager is on again
A copy of this log entry has been emailed to: lkaufman@jlab.org,rsholmes@jlab.org