• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name A. Tobias

    Log entry time 08:06:07 on November19,2005

    Entry number 160645

    keyword=Owl Shift Summary


    Owl Shift Summary

    Did a spectrometer q2 measurement in first hour of shift..
    Taking production data rest of shift. IHWP is IN at beginning of shift.

    SLUG 38 (IN) total so far (approx) =

    Owl Shift Log

    2311:0006 happex run 6554
    xxxx:xxxx spect. run 3099 q2 meas. <-- low current = 0.45uA w/ 1M events
    0028:0040 spect. run 3100 q2 meas. <-- low current = 0.24uA w/ 1M events
    0053:0148 happex run 6555
    0149:0245 happex run 6556
    0245:0341 happex run 6557
    0341:0437 happex run 6558
    0438:0533 happex run 6559
    0534:0630 happex run 6560
    0630:0726 happex run 6561
    0727:xxxx happex run 6562

    People on Shift

    Bob Michaels
    Al Tobias

    Experimental Parameters

    beam current = 58 microamps (0.45uA or 0.24uA during spectrometer q2 measurement)
    target = LH2 in Loop 2 [T = 19.0K, P = 22.2psi, fan frequency = 91Hz]
    left HRS (set) = 3.12340 GeV/c right HRS (set) = 3.11260 GeV/c
    left septum (set) = 323.61 A right septum (set) = 316.92 A
    sweeper magnet (set) = 111.0 A

    Runs Summary

    happex time run# type BHWP equivalent "ok" two-arm pairs (Coulombs)
    2311:0006 6554 production IN 39672 (0.151)
    0053:0148 6555 production IN 26412 (0.101)
    0149:0245 6556 production IN 36601 (0.140)
    0245:0341 6557 production IN 38369 (0.146)
    0341:0437 6558 production IN 35461 (0.135)
    0438:0533 6559 production IN 39091 (0.149)
    0534:0630 6560 production IN 38075 (0.145)
    0630:0726 6561 production IN 34355 (0.131)
    0727:xxxx 6562 production IN running ...

    compton time run# (beam polarization)*(photon polarization) [stat err only] or comments
    2309:0028 12920 -(89.1 +/- 0.9)% end run due to high rates in photon detector > 13KHz during Q2 measurement
    0053:0301 12921 -(89.2 +/- 0.6)% run went fine to 1M events
    0309:0517 12922 -(89.0 +/- 0.6)% HV tripped off to detectors, end run & reboot
    0537:0606 12923 ??
    0607:0607 12924 junk, short run
    0611:0644 12925 -(90.8 +/- 2.3)%
    0650:0727 12926 -(90.6 +/- 1.2)%
    0744:xxxx 12927 running ...

    Other Events

    The Beamline HV (compton) tripped a couple of times, and toward the latter part of the OWL shift, the compton DAQ had a few problems.