Main INDEX
Monthly INDEX
PREV
NEXT
User name paschke
Log entry time 03:00:25 on November22,2005
Entry number 161005
keyword=summary of pb studies so far
Summary of "high-current" lead studies with HAPPEX detector.
23:00 Bob turns beam over to us bozos.
run 6630... Rough profile scan
run 6631... Fine profile scan... reveals weird structure.
run 6632... Q3=+10%, large profile scan.
run 6633... Q3=-10%, fine profile scan
run 6634... Q3 nominal, fine profile scan
run 6635... Q3 nominal, improved scan w/o beam trip
run 6636... Q3 Left = +10%, Q3Right=nominal, x-scan (crappy)
run 6637... Q3 Left = +10%, Q3Right=nominal, x-scan
Run 6638... regression and dithering at 1 uA
HV: Det2: 1740, Det4: 1640
run 6639... regression at 4 uA.
HV: Det2: 1540 Det5: 1440
Widths:
L(2) R(4)
1uA 2105 1829
4uA 1017 851