keyword=Helicity gate check in runend
I added a helicity gate check to run end based on the formula
Let
Tp = time in helicity plus
Tm = time in helicity minus.
T = time of run.
Expect
T - 1.016*(Tp + Tm) = zero.
The residual is an estimate of time loss.