Run 2923 Cosmics while the hall in a controlled access.
Thresholds: NA -50 Preshower -20 BB Tot -20
8:35 BB HV in slots S10-S13 disabled.
In the prompt analysis of run 2922 there are differences between the reference Shower Ap vs. Preshower and 2922 distributions. The shower values went up by ~1000 channels.
9:20 Half Wave plate IN,
9:35 MCC called to inform us to change angle at rotating half-angle
plate
11:30 Alexandre finished with NA
11:45 J.P and Wolfgang finished with the target at the hall
12:03 Continue with cosmics
12:25 Beam delivered however there is a low trigger rate at BB (run 2933)
12:30 We found wrong triggers thresholds
12:41 Raster run, raster size 2X2.5mm
12:41 New Compton run.
12:50 Software problem with the prompt analysis. It crashed during run 2934.
13:00 New threshold value for BB Total sum -160mV.
13:15 Controlled access according to Albert and Aiden request
13:20 Compton coda could not be stopped and rebooted.
13:45 Controlled access is finished.
13:50 We have the beam again.
14:00 New Compton run
14:05 Raster run, raster size 2X2.5mm