    User name R. Michaels

    Log entry time 16:53:31 on March17,2006

    Entry number 167088

    keyword=Trig. checks.

    A couple checks

    1. Sergey asked about the ADC gate for 1182 for BPM/raster.
    It is flipped polarity (sloppy) but it goes to another module
    which re-generates an adjustable gate and that has correct polarity.
    Result is a 200 nsec shift in gate (which is stable). But we
    have time shifts anyway between BPM & event data which need to
    be worked out. So its ok, actually negligible, and I'll leave it.

    2. Looked at retiming on RT module. The L1A appears 42 nsec
    before the BB RT pulse. Meanwhile at the coinc. overlap the
    44 nsec wide N-arm trig. appears 32 nsec after the start of
    the 100 nsec wide BB trig, so as N-arm slides 68 nsec later
    the L1A will run into the RT. We could alleviate this by adding
    26 nsec to the BB RT, but would need to check BB ADC, so I'll
    leave it for now. When N-arm slides late, the BB will have
    timing from N-arm during the last 26 nsec of the randoms. That
    is sloppy, but correctable using other info in the data.