• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name S.Abrahamyan

    Log entry time 21:44:41 on April 02, 2006

    Entry number 169334

    keyword=Shift summary 17-21

    Runs during shift: 3606, 3607,

    Online GUI:
    channel n5 40 L HV is turned on (should be turned off:noisy channel).
    turned on after run 3606.

    BCA:
    run 3606:
    u1 : 45.61 ppm u3 : 47.14 ppm u10: 47.09 ppm
    d1 : 47.06 ppm d3 : 49 ppm d10: 46.7 ppm
    run 3607
    u1 : -0.53 ppm u3 : 5.65 ppm u10: 6.63 ppm
    d1 : 11.28 ppm d3 : 7.70 ppm d10: 5.96 ppm
    run 3608;
    u1 : 3.13 ppm u3 : -0.08 ppm u10: 2.67 ppm
    d1 : 3.48 ppm d3 : 1.06 ppm d10: 1.66 ppm
    Information about assimetry from scalers is in attached plots.

    Tracking efficiency, DC eff. X and Y positon for 3606 from tracking are
    in attached files.





    assimetry from scalers 3606

    qasyfit3606.ps

    assimetry from scalers 3607

    qasyfit3607.ps

    assimetry from scalers 3608

    qasyfit3608.ps

    DC eff run 3606

    3606_eff.ps

    tracking eff run 3606

    3606_trackefficiencies.ps

    X and Y from tracking run 3606

    3606_showerXY.ps