• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name kelleher

    Log entry time 16:48:49 on April 06, 2006

    Entry number 169781

    keyword=Target polarization measurement

    Performed an NMR-EPR calibration. We asked for beam to be taken away at
    15:48, and asked for beam back at 16:01.

    The measurement includes many AFP sweeps, and as a result, we have lost
    some polarization due to the measurement.

    Our final NMR result is listed below:

    Lower Coils:
    X
    UP = 118.2 mV +/- 0.785
    DOWN = 117.7 mV +/- 0.881

    Y
    UP = 3.730 mV +/- 0.079
    DOWN = 3.179 mV +/- 0.087

    Upper Coils:
    X
    UP = 1.466 mV +/- 0.009
    DOWN = 1.432 mV +/- 0.012

    Y
    UP = 0.7316 mV +/- 0.0075
    DOWN = 0.7619 mV +/- 0.013

    Polarization = 50.9%