User name A. Puckett
Log entry time 00:12:01 on April 11, 2006
Entry number 170272
keyword=Swing Shift Summary
At the start, things appear to be running smoothly, no special plans for
the shift. Current run numbers are 3818 (GEn), 13349 (Compton), 7319
(Parity). There was a problem near the end of Compton run 13349,
unfortunately it's too late to get a screen capture, but what I observed
was that the Compton electron rate was very high, about 180 kHz/muA, and
the photon and coincidence rate was nil. So I looked at the beam position
monitor, and it had drifted far off from the set values, so I called MCC
and they fixed the problem, they said there was a "mismatch" in one of
the quads in the Hall A beamline. I cycled the Compton, GEn, and parity
runs, and everything looks OK now, but be on the lookout for some junky
data near the end of each of those runs.
An NMR measurement at about 19:53 yielded polarization of 51.0 %.
At maybe 22:00, give or take an hour, I asked MCC to tweak the beam
position, it was looking good after the quad mismatch fix, but had been
slowly drifting upward in the vertical coordinate all night, it got to
BPMA_Y = 1.5 and BPMB_Y = 0.12, I asked them to try and nudge it down to
1.4 and 0.0 and they did, and it looks good.
At the end of run 3285, we plan to move to the reference cell position,
we will have been evacuating the reference cell for about 40 minutes, and
start to take some runs on the ref. cell, we will vary the raster size
and record the BB DC leakage currents.
GEn
Run # Start Stop Nevent Replay OK? Comments
3818 15:44 16:36 1.6M Y quad mismatch happened
during this run near the middle of the run, BPM's drifted far from set
values.
3819 16:43 17:43 2.0M Y
3820 17:43 18:49 2.0M Y
3821 18:49 19:53 2.0M Y NMR after this run
3822 19:57 19:58 small Y Short run for spot
check, look good, 2x2 at target
3823 19:59 21:03 2.0M Y
3824 21:04 22:08 2.0M Y
3825 22:08 23:10 2.0M Y
3826 23:22 reference cell vacuum
run, spot check, vary raster size
runs 3827-3830: (see entry of Nilanga) changed raster size, observed BB
DC leakage currents, and adjusted HV, all with empty reference cell at 8
muA. After leaving, plan is to fill ref. cell with hydrogen and run for
an hour, then go back to normal running.
Parity
Run # Start Stop Nevent Aq Comments
7320 16:34 18:03 160K -42.6 +- 18.3
7321 18:05 19:53 185K don't know final value but was
small for most of run
7322 19:57 21:34 171K -11.5 +- 16.0
7323 21:34 23:23 191K 2.74 +- 16.56
Compton
Run # Start Stop S/N Pe*Pg Comments
13349 15:48 16:24 15.7 88.8 Hall A quad
mismatch last 9 minutes of this run.
13350 16:29 18:03 6.6 86.0
13351 18:04 19:32 4.5 85.6
13352 19:32 19:54 2.7 80.8 short run,
stopped early for NMR when GEn run 3821 ended
13353 19:57 21:35 5.3 86.1
13354 21:36 23:23 5.6 84.8