User name R. Michaels
Log entry time 16:48:28 on September27,2006
Entry number 185599
keyword=Switched to 1-daq mode
Alex and I made an access and switched the DAQ to 1-daq mode.
The users should use the CODA config "TWOARM" which is the first
in the list (a-onl account on adaql2). The "LeftHRS" config should
not be used.
The triggers are, as usual
T1 = Main R-arm scint.
T2 = R-arm effic.
T3 = Main L-arm scint.
T4 = L-arm effic.
T5 = L-R coincidences = T1.and.T3
T6 exists if S0 exists (T6 = S0.and.T3)
T8 = 1024 Hz pulser
T9 = 30 Hz helicity pulse (cannot prescale it)
The only differences to how we were running LEDEX up to now:
1. You now have a T5 trigger with full readout of both HRS.
2. You still have singles triggers, of course, but the maximum
rate of the DAQ is effectively 1/2 what it was in "2-daq" mode.