Main INDEX
Monthly INDEX
PREV
NEXT
User name X. Jiang
Log entry time 14:09:12 on September29,2006
Entry number 185879
keyword=rate at ep kin-3.
Rate estimate for kin-3 ep.
At E0=0.684, theta_e=61.4, E'=0.497, p_p=0.62, theta_p=44.18.
12.9 uA beam on 15 cm LH2 target, luminosity=5.1*10^37 cm^-2 s^-1.
for 6 msr electron arm solid angle, electron elastic singles rate
should roughly be about ~7 kHz.
Run 5349 for example, at I=3 uA, electron singles rate should be about 1.6 kHz. We have T1= 1.2 kHz, T5=0.76 kHz, add up roughly right.
Since we are not doing elastic cross section measurements in the next few days, as long as we record coincidence events, we will be fine in the data analysis.
If we clearly see evidence of ctime off, we should tune it to be
roughly right. Otherwise, we will just need to take T5 events and increase the beam current.
Xiaodong Jiang. Run coordinator.