keyword=Right Arm after ESR Trip & magnet Quench
After yesterday evening's ESR crash, all of the magnets quenched and had to be completely reset. It looks like the HRS-R momentum came back slightly shifted from the original momentum setting. This started with run 1580, the first run after the HRS-R recovered, and has been consistent.
We can see nothing wrong with the NMR readings, and it has been locked since the resetting of the magnets.