Main INDEX
Monthly INDEX
PREV
NEXT
User name eschulte
Log entry time 00:11:20 on October 27, 2006
Entry number 188357
keyword=Swing Shift Log
16:00 Shift starts taking production data on 4He 10 cm target, 55uA, run#
1766.
19:01 MCC takes beam to reconfigure Hall B.
19:00 to 21:00 Hall B setup no beam.
20:48 MCC called to let us know they are ready to send beam back.
Requested 55uA. Begin data taking with run #1768
21:08 HRS-L Q3 drift
23:49 Possible HRS-L NMR lock lost and then regained. The NMR seems to
be OK, but the signal abruptly changed value (on a highly blown up
scale). Effected run 1769. See Entry: 188354
23:55 Reboot both HRS-L & HRS-R IOC's and HRS-R NMR. The readings
appeared frozen, although the NMR for both looked OK. After reboot, the
HRS-L didn't seem to come back quite right so the Owl shift rebooted the
left again.