Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 14:56:26 on November29,2006
Entry number 189482
keyword=adjust delay for TCL
The coinc. time measured on L-arm was too close to the end
of the TDC range, so we adjusted the delay there by 96 nsec.
The R-arm TC, meanwhile, looked ok.
There is an issue with the EDTM pulser that during checkout we
have to add a 50 nsec cable to S2 on L-arm in order to get the
delays right. This is because of the "broken symmetry" whereby
one arm has S2 and the other S2m, and the way the pulser is
connected. I don't feel like explaining it all here, but the
upshot is that the EDTM pulser doesn't appear on top of the
physical coincidence peaks when we remove this 50 nsec cable
to perform production running (as it is now). In the future
we should modify these EDTM modules to provide more delays
to accomodate this unexpected way of running (S2 & S2m) so that
the pulser setup is exact.