User name suleiman
Log entry time 02:01:19 on December 1,2006
Entry number 189615
keyword=Hall C Energy Modulation
Hall C does coil modulation once every three runs (approximately
every 3 hours). It takes 3 mintues to go through the modulation
cycle. Fisrt they move the position in Hall C line, so this affects
only Hall C. For the last minute, the energy is changed by
+/- 5X10^-5.
The EPICS variable that shows they are doing modulation is:
BMWCALC.I
=====================================
DESC: subroutine record
RTYP: sub
TYPE: DBF_DOUBLE
COUNT: 1
ACCESS: R
IOC: iocsb4.acc.jlab.org:5064
VALUE: 0.000
STAMP: Fri Dec 01, 2006 01:47:340.159
ALARM: NO
and it will be set to -0.7 during the cycle. The other variable that
shows the energy modulation is: HCBMWCALC.J and it will step from
-0.050, ... , 0.050.
To open the screen that shows the modulation cycle in Hall C:
From Monticello Screen: click on the yellow button next to Magnets,
click "3C" at the far left and choose "3C Position Modulation
Control"
FIGURE 1