• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name R. Michaels

    Log entry time 15:50:30 on February 5,2007

    Entry number 191441

    keyword=removed 50nsec L-arm RT

    Removed 50 nsec from the L-arm retiming (RT) which I had put in
    a couple days ago. It was an error. Removing this keeps the
    analog data in the gate, and improves the TDC dynamic range.