    User name Makis Petratos

    Log entry time 00:02:03 on February12,2007

    Entry number 192447

    keyword=SHIFT SUMMARY

    Shift started with machine down due to gun/injector
    problems. After fixing a DAQ crash problem started
    taking data for kinematics G (left HRS at 51 deg).
    (For gun story see ELOG entry # 1357650)

    Completed Ta and C running at this kinematics:
    Two one-hr runs for each target. Ta: 5uA both runs.
    C: one run at 5uA and another one at 10uA

    RUN SUMMARY
    6225(L)/26201(R) 16uA Ta 470K events(L)
    6226(L)/26202(R) 15uA Ta 489K "
    6228(L)/26204(R) 5uA C 616K "
    6229(L)/26205(R) 10uA C 1.0M

    At 11:55 we changed target to Boron. Took test run
    at 10uA: Rates at right arm were too high and VDCs
    were drawing too much current ~20uA. Lowered current
    to 5uA to keep VDCs at ~10uA.

    Runs not listed above are test runs to set prescales