Log entry time 00:00:11 on March 6,2007
Entry number 194898
keyword=swing shift summary
16:00 Still waiting for MCC to allow controled access to move the HRS.
16:45 At the request of MCC we conducted a HARP scan.
the harp's run number is 2321.
/DATA/arc/ARC/scan_2321.data
Results are:
Scanner 5: H.sigma=174um V.sigma=160um
Scanner 6: H.sigma=165um V.sigma=121um
17:20 Hall access, got Ed's premission to move LHRS
17:25 moving LHRS to 22.41
17:30 MCC says beam is ready.
17:55 Took another HARP scan with 5uA.run number 2322 results:
Scanner 5: H.sigma=157um V.sigma=111um
Scanner 6: H.sigma=147um V.sigma=119um
18:04 15uA - T3 is 600Hz at -4,2
15uA - T3 is 3KHz at -6,5
15ua - T3 is 600Hz at -2,5
15uA - T3 is 600Hz at -2,1
15uA - T3 is 900Hz at -6,-1
15uA - T3 is 3.6KHz at -7,2
15uA - T3 is 22KHz at 2,2
15uA - T3 is 600Hz at -3,2
15uA - T3 is 640Hz at -5,5
15uA - T3 is 600Hz at -1,5
15uA - T3 is 580Hz at -1,-1
15uA - T3 is 600Hz at -5,-1
15uA - T3 is 600Hz at -3,2
18:25 decided to go with beam center at -3,2 we're getting T3=600Hz at 15uA. Raster size is 4X6.
20:30 MCC droped us to 47uA on run No1188 to do some tests.
22:05 taking a run with pulser only,to investigate the strange raster distribution - all prescales set to 65535 except T8=3.
22:25 Beam center moved to -2.5,2 and then to -3.5,2 for spot runs
22:35 Beam center moved to -3,2, this solved the strange raste distribution and so we'll take a 2hr production run with this beam position.
23:50 MCC droped us to 35uA, to run tests of the last hour beam trips.
23:55, shift end, Production run 1193 still running on Pb, beam has not been stable for the last 20min.
1175 - harp scan, file name:/DATA/arc/ARC/scan_2321.data
1176 - harp scan, file name:2322.data
1177 - spot run, MCC still tunning raster, stopped the scan
1178 - spot run. raster size is 4X6 T3=600Hz, 5uA
1179 - Iscan on C target 5.9uA
1180 - Iscan on C target 10uA
1181 - Iscan on C target 21uA
1182 - Iscan on C target 42uA
1183 - Iscan on C target 53uA
1184 - Iscan on Pb No.4 5uA
1185 - Iscan on Pb No.4 10uA
1186 - Iscan on Pb No.4 20uA
1187 - Iscan on Pb No.4 40uA
1188 - Iscan on Pb No.4 52uA-47uA 5M events
1189 - IScan on Pb No.4 47uA
1190 - A Pulser run to investigate the strange raster distribution
1191 - spot run, beam center moved to (-2.5,2)
1192 - spot run, beam center moved to (-3.5,2)
1193 - Iscan on Pb No.4 53uA beam center is at (-4,2)