Main INDEX
Monthly INDEX
PREV
NEXT
User name C. Fernandez-Ramirez
Log entry time 08:05:31 on March17,2007
Entry number 196256
keyword=Owl Shift Summary
Production on Pb#3
Run 1611 00:09-00:17, 10 uA on Pb#3 at kin05, total= 0.044 C
Run 1612 00:18-00:27, 20 uA on Pb#3 at kin05, total= 0.014 C
Run 1613 00:30-00:48, 40 uA on Pb#3 at kin05, total= 0.053 C
Run 1614 00:49-01:04, 40 uA on Pb#3 at kin05, total= 0.091 C
Run 1615 01:05-01:28, 40 uA on Pb#3 at kin05, total= 0.145 C
Run 1616 01:29-01:50, 40 uA on Pb#3 at kin05, total= 0.199 C
Run 1617 01:51-02:14, 40 uA on Pb#3 at kin05, total= 0.253 C
Run 1618 02:15-02:36, 40 uA on Pb#3 at kin05, total= 0.307 C
Run 1619 02:37-03:11, 40 uA on Pb#3 at kin05, total= 0.361 C
Run 1620 03:12-03:35, 40 uA on Pb#3 at kin05, total= 0.415 C
Run 1621 03:36-03:58, 40 uA on Pb#3 at kin05, total= 0.470 C
Run 1622 03:59-04:21, 40 uA on Pb#3 at kin05, total= 0.524 C
Run 1623 04:22-04:43, 40 uA on Pb#3 at kin05, total= 0.578 C
Run 1624 04:44-04:55, 40 uA on Pb#3 at kin05, total= 0.603 C
04:55 MCC Called: Raster power supply broke, moving to empty target
04:58 Calling Raster-on-call Bill Gunning
05:00 Asked a Controlled access to replace the power supply
05:15 Controlled access, R. Michaels in to diagnose
05:20 Go to building 90 for a power supply
05:40 R. Michaels and C. Fernandez in Hall to replace the raster power supply
06:10 Raster power supply replaced
Run 1625 06:15-06:17, test run for the raster, empty target
Run 1626 06:25-06:40, 10 and 20 uA on Pb#3 at kin05, total= 0.618 C
Run 1627 06:41-07:05, 40 uA on Pb#3 at kin05, total= 0.672 C
Run 1628 07:06-07:28, 40 uA on Pb#3 at kin05, total= 0.726 C
Run 1629 07:29-07:52, 40 uA on Pb#3 at kin05, total= 0.781 C
Run 1630 07:53-Next shift