keyword=EPICS start of run test
It looks EPICS variable came back quickly after reboot.
I tried changing back the environment variable to 4 instead of 12 right
now and the script work fine. So the gateway is set correctly in the
EPICS script ( as I kinda expected ) as Bob pointed out it.
Anyway better to use 129.57.255.12 for everything so I leave the
environment variable to this one so we can query spectrometer variables
from shell.
So it works now, but we still don't know why it was failing some time
ago... but yes as long as it works we are happy !