• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name spiegel

    Log entry time 13:30:54 on March 27, 2007

    Entry number 197550

    keyword=Hall A post -beam Systems check out

    Began Bogie system checks at 09:30 a.m. Pulled up RIGHT controls screen, turned on system and moved right bogies CCW .5 degrees. Then CW from appox 32.0 DEG. to 45.0 Deg. Also, adjusted Right front angle camera + and minus directions. Tried to pull up LEFT controls and had no response. Reset LEFT bogie controls crate. I was able to pull up the controls screen and turn on the Left bogies. Moved bogies CW .5 DEG then continued to move RIGHT spectrometer CCW form 22.0 Deg to 45.0 Deg. Tried to move the Angle Camera and had no response. Reset motor controller under Spectrometer arm and was able to move camera + and - directions. Continued tests of the LEFT collimator and moved it to all three positions. Currently set in OPEN. Will follow up testing of RIGHT collimator when the Right spectromter SLOW controls are reestablished.

    A copy of this log entry has been emailed to: folts@jlab.org,stevensm@jlab.org,segal@jlab.org