Main INDEX
Monthly INDEX
PREV
NEXT
User name M. Olson
Log entry time 08:04:58 on May20,2007
Entry number 202755
keyword=Owl Shift Summary
Owl Shift Summary:
M. Olson, B.Hahn
0004: Prescales set for Al dummy target
0008: BeO target in beamline
0045: Decision made to not run dummy target. Prescales reset for He3.
Requested Harp scan on BeO target (5uA) raster off.
0126: Raster off, 5uA, Harp scans commencing. Beam position good on camera and on BPM's
0137: Harp scans complete (x = 116uA, y = 207uA)
0151: Restored raster (spot++ OK).
Verified beam position and feedback
Masked target motion to mover He3 target into beamline
He3 prescales verified
PS1=2100, PS2=168000, PS3=2, PS4=200, PS5=PS6=PS7=1
0155: He3 in beamline, requesting 105uA
0232: 100uA beam established, starting production with run 3646
0326: End run 3646 (He3 Production, 1.25M)
0417: End run 3647 (He3 Production, 1.25M)
0450: Noticed that DT=100% and ROC2 died
End run 3648 (He3 Production, 500k, no endrun)
Rebooted ROC2
Killed and Restarted CODA
0452: Start run 3649
0548: End run 3649 (He3 Production, 1.25M)
0655: End run 3650 on 15min loss of beam (He3 production, 1.0M)
0700: Beam back, start run 3651
0754: End run 3651 (He3 Production, 1.25M)
Run 3652 in progress at end of shift