Main INDEX
Monthly INDEX
PREV
NEXT
User name sawatzky/gilman
Log entry time 16:32:12 on June 08, 2007
Entry number 204763
keyword=Radiator stepper motor voltage settings
We need to have the stepper voltage at 18V minimum (which is the voltage
we are using now). If the voltage is lower than that the motor motion is
smoother, BUT the motor gets "stuck" at the UL (radiator out) limit switch.
Pulse Generator: 100 Hz, 100 Hz square wave 0V min, +2V max. *** Confirm
the pulse on the scope. ***
For the Stanford Model DS345 unit we have now the function generator
settings to get what we need are: 100 Hz, 1V amplitude, 0.5V offset.
This generates the needed 0--2V square wave on the scope. Go figure.
A copy of this log entry has been emailed to: gilman@jlab.org