kinematic: 2.5 GeV, P(Left HRS)=0.93GeV/c, thetaLab(Left HRS)=105.26
P(Right HRS)=2.781GeV/c, thetaLab(Right HRS)=18.83
16:15 - run 1515 is going on.
run 1514-1517: He3 target, Radiator IN.
run 1517 : The "end of run" was sent after the next run was started.
1518: He3 target, Radiator OUT.
1519: Junk run - very short because we didn't change the prescalers.
1520-1522: He3 target, Radiator IN.
10:15 - we got ready to move to the next kinematic point - 12C
We checked visually that the way is clean and started the procedure according to the "How to":
The Left HRS had problems moving, but it moved at the end (limits on current were increased) : 85 degrees, Vernier: -14
Right HRS was moved to: 27.5 degrees, Vernier: ~ -16.5
Momentum of Left HRS: 1.196 GeV/c
Momentum of Right HRS:
---- New kinematic point 12C: 2.457GeV, th(RHRS)=27.599, P(RHRS)=2.57GeV/c, th(LHRS)=84.74, P(RHRS)=1.196 ----------------
23:11 - Take optic run: 1523, optic target, radiator out
23:35 - Take production data:
run 1524: He3 target, Radiator IN.