• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name S. Sirca

    Log entry time 15:32:50 on November 9,2007

    Entry number 213241

    Followups:

    keyword=Right HRS Q1 oscillates slightly

    In the 403.987 MeV/c setting for HRS Right, the Q1 fluctuates
    slightly (current roughly between 300.0 and 300.6 Amps).
    Can not bring it to stay calm with any known tweak.
    I learn that this is due to the low momentum p < 450 MeV/c
    when the regulation is tied to the Hall probe.
    Take HRS Right runs from here on (run 20636) anyway.
    Can decide later if they are to be scrapped.