    User name a-onl

    Log entry time 14:47:39 on November 11, 2007

    Entry number 213819

    keyword=End_of_Run_2273
    ****************************
     Run Number: 2273
     End of Run Comment:
    Run_type=Production,target_type=Carbon 50 degs Right,beam_e0=0.845,beam_raster=on,leftarm_p=0.153071,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.169184,rightarm_theta=120,rightarm_colli=out,comment_text=Right arm ramping down to 153.071 MeV/c
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=1   ps4=1   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 511920       
    TIME     : 23.900 mins  
    
    DEAD TIME:   5.87%      
    
    TRIGGER RATES:   PRES/REAL
    T3:356.6/356.6 Hz   T4:22.6/22.6 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 511405/511405   T4:  32472/32472    T5:      0/0        T8:     22/1468407  
    
    AVERAGE CURRENT
    BCM x1 : 47.7823uA  BCM x3 : 48.7998uA  BCM x10: 43.0285uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.0683         BCM u3 : 0.06828        BCM u10: 0.06126        
    
    BCM d1 : 0.06874        BCM d3 : 0.07168        BCM d10: 0.06214        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2273 at Sun Nov 11 14:47:35 EST 2007
    
    Wien angle : 37.5018
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.153022
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.152999
    Right Arm arm angle : 120
    HALLA:p : 1646.71
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1646.71
    Left Arm Top VDC Current : 2.29492
    Left Arm Bottom VDC Current : -1.51367
    Left Arm Q1 momentum : 0.152895
    Left Arm Q1 power supply : 112.047
    Left Arm Q1 gauss meter : -0.009471
    Left Arm Q2 gauss meter : 0.03491
    Left Arm Q2 power supply current : 64.4519
    Left Arm Q2 momentum : 0.152839
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 49.0295
    Left Arm D1 momentum : 0.153077
    Left Arm D1 NMR : 0.342415
    Left Arm Q3 gauss meter : -0.02982
    Left Arm Q3 power supply current : 58.4327
    Left Arm Q3 momentum : 0.153032
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.151909
    Right Arm Q1 power supply : 111.78
    Right Arm Q1 gauss meter : -0.002885
    Right Arm Q2 power supply current : 64.8424
    Right Arm Q2 momentum : 0.152877
    Right Arm Q2 gauss meter : 0.03457
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 48.7153
    Right Arm D1 momentum : 0.153026
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 59.9637
    Right Arm Q3 momentum : 0.152916
    Right Arm Q3 gauss meter : 0.02704
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 48.0382
    Current on Unser monitor : 58.9485
    Current on Upstream bcm : 48.0194
    Current on Downstream bcm : 48.057
    Upstream Cavity Coefficient : 44
    Downstream Cavity Coefficient : 43.854
    Current on IBC0L02 (source) : 94.8193
    Hall C Current : 47.01
    MBSY1c magnet current (amp) : 34.8338
    MBSY1c Bdl : 210847
    Hall A momentum (Tiefenbach) (HALLA:p) : 1646.71
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 845
    Hall A energy (halla_MeV) : 1646.71
    Hall C energy (hallc_MeV) : 4048.41
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.395931
    IPM1H04A.XPOS : -0.916902
    IPM1H04A.YPOS : 0.0294076
    IPM1H04B.XPOS : -0.994861
    IPM1H04B.YPOS : 0.0216356
    Left Arm Collimator : 0.871289
    HacL_HPE1313A:0_Ch58 : -0.319336
    HacL_HPE1313A:0_Ch55 : 22.6562
    HacL_HPE1313A:0_Ch54 : -0.282227
    SLI data valid? : No
    SLI horiz size mm : 0.0355341
    SLI Energy spread *10^5 : 0.658038
    SLI x position : 1.24472
    SLI vert. size mm : 0.193521
    SLI y position : 3.04225