• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 04:33:20 on November 30, 2007

    Entry number 217209

    keyword=End_of_Run_3059
    ****************************
     Run Number: 3059
     End of Run Comment:
    Run_type=Production,target_type=Carbon 50 degs Right,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.12418,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.15321,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   ps4=2   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 142800       
    TIME     : 10.280 mins  
    
    DEAD TIME:   4.27%      
    
    TRIGGER RATES:   PRES/REAL
    T3:217.1/217.1 Hz   T4:24.8/49.6 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 133892/133892   T4:  15289/30578    T5:      0/0        T8:      9/631595   
    
    AVERAGE CURRENT
    BCM x1 : 50.0274uA  BCM x3 : 50.1114uA  BCM x10: 43.4570uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.03092        BCM u3 : 0.03092        BCM u10: 0.02658        
    
    BCM d1 : 0.03079        BCM d3 : 0.0309         BCM d10: 0.02703        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3059 at Fri Nov 30 04:33:17 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.133174
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.123975
    Right Arm arm angle : 120
    HALLA:p : 645.872
    HALLA:dpp : -3.98295e-05
    Tiefenbach Hall A energy : 645.872
    Left Arm Top VDC Current : 4.78516
    Left Arm Bottom VDC Current : 0.878906
    Left Arm Q1 momentum : 0.133025
    Left Arm Q1 power supply : 98.2681
    Left Arm Q1 gauss meter : 0.008811
    Left Arm Q2 gauss meter : -0.0301
    Left Arm Q2 power supply current : 55.7536
    Left Arm Q2 momentum : 0.133064
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 44.3051
    Left Arm D1 momentum : 0.13309
    Left Arm D1 NMR : 0.347682
    Left Arm Q3 gauss meter : 0.02735
    Left Arm Q3 power supply current : 51.0356
    Left Arm Q3 momentum : 0.133018
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.125027
    Right Arm Q1 power supply : 90.5241
    Right Arm Q1 gauss meter : -0.002378
    Right Arm Q2 power supply current : 52.3936
    Right Arm Q2 momentum : 0.124017
    Right Arm Q2 gauss meter : 0.02804
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 35.7874
    Right Arm D1 momentum : 0.12392
    Right Arm D1 NMR : 0.340703
    Right Arm Q3 power supply current : 48.4779
    Right Arm Q3 momentum : 0.124146
    Right Arm Q3 gauss meter : 0.02188
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.2855
    Current on Unser monitor : 60.9084
    Current on Upstream bcm : 49.3829
    Current on Downstream bcm : 49.1881
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.306
    Hall C Current : 79.2
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 645.873
    Hall A momentum orbit correction (dpp) : -3.80778e-05
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 645.873
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.71012
    IPM1C12.XPOS : -0.0627776
    IPM1H04A.XPOS : -1.0852
    IPM1H04A.YPOS : -0.0759918
    IPM1H04B.XPOS : -0.989121
    IPM1H04B.YPOS : 0.00779265
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.6074
    HacL_HPE1313A:0_Ch54 : -0.281738
    SLI data valid? : Yes
    SLI horiz size mm : 0.310752
    SLI Energy spread *10^5 : 5.75467
    SLI x position : 1.13292
    SLI vert. size mm : 0.105899
    SLI y position : 1.7277