User name MinaKat
Log entry time 00:04:55 on December20,2007
Entry number 222311
keyword=Shift Summary
Shift Summary:
===============
4:15 Finished BCM calibrations (started in previous shift)
We proceed with H2/He target boiling test (part #2)
Asked for beam raster 2x2, set at BPM A and B at -2mm
Momentum set (both arms): 2.791 GeV/c, angle (both arms): 15 deg
Target: He Loop 1, raster 2x2
-------------------------------
Run (Right/Left) Current(uA) Events (Right/Left)
------------------------------------------------------
22173/4317 5
22174/4318 10 0.7M/0.3M
22175/4319 20 1.2M/0.7M
22176/4320 30 1.4M/0.6M
22177/4321 40 0.9M/0.5M
22178/4322 50 1.2M/0.6M
22180/4324 60 1.1M/1.1M
22181/4325 70 1.1M/1.1M
Left Spectrometer problem: when quads were cycled, regulator was not
set back for Runs 22173 - 22178. Boiling tests are ok for the Right
spectrometer. Set regulator on.
1
22179/4322 test.
Target: C12 Left, ratster 2x2
-----------------------------
Run (Right/Left) Current (uA) Events (Right/left)
---------------------------------------------------------
22182/4326 5 0.1M/0.1M
22183/4327 10 0.3M/0.3M
22184/4328 20 0.5M/0.5M
22185/4329 30 0.5M/0.4M
22186/4330 40 0.7M/0.7M
22187/4331 50 0.8M/0.8M
22188/4332 60 0.5M/0.5M
22189/4333 70 0.6M/0.6M
Target: He Loop 1, raster size 3x2
----------------------------------
Run 22190 test raster size
Run (Right/Left) Current (uA) Events (Right/Left)
--------------------------------------------------------
22191/4335 5 0.4M/0.4M
22192/4336 10 0.8M/0.8M
22193/4337 20 1.0M/1.0M
22194/4338 30 1.0M/1.0M
22195/4339 40 1.1M/1.1M
22196/4340 50 1.0M/1.0M
22197/4341 60 1.0M/1.0M
22198/4342 70 1.0M/1.0M
Momentum set (both arms):2.573 GeV/c
Target: H2 Loop 3, raster size 2x2
----------------------------------
Run 4343 test raster size 5uA (good run)
20:44 While right spectrometer dipole is setting, Alex will do
NaI HV balancing. So put optics target in.
Runs 4344,4345,4346 HV tests
21:10 Dipole finally settles, put H2 Loop 3 target back in
Target: H2 Loop 3 raster size 2x2
---------------------------------
Run (Right/Left) Current (uA) Events (Right/Left)
------------------------------------------------------------------
22199/4347 5 Right/Left spect. IOC die
21:16 Right IOC dies. Rebooted (during 5uA runs 22199/4347), Dipole NMR will not lock. Next we loose Left IOC.....Cannot reboot from hareboot10
Paged tech on call,
Tech is on his way, asked for hall entry
1 hour later right dipole NMR finally locks.
22:40 Tod in hall
J.P.'s instructions:
1) scratch remaining boiling test points.
2) proceed with item 3 (Optics) on Runplan.
3) run with the right spectrometer only, if IOC
problems persist.
23:45 Tech still in hall, Alex goes in too.
00:01 Alex calls from hall. Network switch was down.
We just got back the left spectrometer display in Hall A tools.!!!!!