• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name R. Michaels

    Log entry time 16:14:03 on March18,2008

    Entry number 228665

    keyword=LeftHrs config

    If you want to check the L-HRS, you may run the LeftHrs config in
    CODA on adaql2 on a-onl account as usual.

    You can also use the config "TWOARM" which is the full readout, but
    note that it takes 66 sec to download the drift chamber crates, and
    runcontrol will complain (don't worry, just wait). However, LeftHrs
    downloads fast. The difference is that LeftHrs only reads the L-HRS.

    The trigger is T3 as usual. To turn off the EDTM pulser (appropriate
    for cosmics tests):
    ~atrig/edtm/edtmdisable

    To turn on EDTM pulser (needed for timing setup):
    ~atrig/edtm/edtmsetup (with appropriate args)

    The prescale factor is 200 so the rate is 500 Hz at the moment.

    The scalers on L-HRS have a permanently-on gate until the gate from
    Bigbite TS can be arranged.