Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 13:40:31 on March28,2008
Entry number 228913
Followups:
keyword=scaler & trigger notes
I moved bcm u3 from the 7th scaler channel of the
normalization scaler, to make room for T7. So, u3 is
now in the 17th channel. I took care to move the fanout
which people had put in for bigbite.
The scaler.map file was updated in ~adaq/e04007/scaler
and subdirectories there, as well as in ~a-onl/scripts.
Here are the trigger definitions and locations in L-HRS scalers:
trigger .... channel ... definition
1 ....... 1 ....... bigbite E plane
2 ....... 2 ....... bigbite dE plane
3 ....... 3 ....... L-HRS S1.and.S2 (as for 10 years)
4 ....... 4 ....... L-HRS efficiency (2 out of 3)
5 ....... 5 ....... T1.and.T7 (but initially T1.and.T3, see note A)
6 ....... 6 ....... T2.and.T7 (but initially T2.and.T3, see note A)
7 ....... 7 ....... (middle 2 paddles of S1).and.S2
8 ....... 8 ....... 1024 Hz pulser (aka clock)
Note A: Inital definitions of T5,T6 will exist during a calibration
phase, then switch to using T7 instead of T3.