    User name Lindgren

    Log entry time 05:40:08 on April 01, 2008

    Entry number 229291

    keyword=Partial Shift Summary

    Changed calibration coefficients to match BCM current reading with MCC Harp scan done Centered beam on BeO 1 ua on Carbon See Log book entry for photograph of scalers DE Rates varied from 15 to 200 KHz, Higher rates correspond to the lower PMTs E rates varied from 2 to 25 KHz, Higher rates correspond to the lower PMTs 1 ua on BeO Rates roughly doubled compared to above 1 ua No Target, Rates dropped roughly by a factor of 100

    Turned on Raster Put in 6 cm LH2 target no collimstor High voltage tripped on E and dE PMTs Turn on one PMT Count Rate is 800 KHz. Perhaps beam may not be aligned well enough with target center. Also 2 mm x 2 mm may be too large

    Put C target back in Take quasi elastic data in L HRS. Run 2101 Look at histogram of data along x. See Quasi elastic peak. Degauss Q3 Lower current to 0 and raise to 1400 A. Regulate back to original value. Take another quasi elastic run on C. Run 2102