    keyword=ESR tripped at noon time. Taregt warmed up. Recovering now.

    ESR tripped ~ noon time. Our target warmed up. Turned down fan speed for bioth loops to 10% (24 Hz). We stayed at cold return (neither MCC, nor cryo asked us to switch). With ESR recovered pretty fast, we started to get ESR flow (~10 g/s). Both loops started to cool-down. The return temperature is ~30K.
    I adjusted J-T slightly to have more on loop1 (LH2) and less on loop 2
    (LD2).