Main INDEX
Monthly INDEX
PREV
NEXT
User name V. Sulkosky
Log entry time 18:23:57 on April 20, 2008
Entry number 233404
This entry is a followup to: 233311
keyword=Helicity and Charge Asymmetry
I looked into the problem that Alexandre mentioned in Halog 233311. It
seems that the problematic runs have a large charge asymmetry. This began
last night with run 3444 and continued until run 3463. After this point,
the charge asymmetry was exceptionally good for runs 3464 to 3519. Then
the charge asymmetry was somewhat larger for runs 3520 and 3521. This is
all based on the end-of-run file, which has been know to have problems.
Dustin was running the HAPPEX DAQ last night until midnight and then
started a run around the beginning of swing shift tonight. So there seems
to be some correlation with the HAPPEX DAQ running. Dustin is looking into
this.
Tomorrow, I will check the charge asymmetries from these runs to verify
that it was indeed high.
A copy of this log entry has been emailed to: mcnulty@jlab.org,moffit@jlab.org