Main INDEX
Monthly INDEX
PREV
NEXT
User name Norum
Log entry time 20:01:50 on April30,2008
Entry number 236005
keyword=Stop data taking; beam retune
19:00 Run L4440 started; production on H2; I=3.4 uA
19:06 BB HV S14 & S0 trip
19:12 Run L4441 started; production on H2; I=3.4 uA
19:18 BB HV S6 & S4 trip; then S14
19:22 Run L4442 started; production on H2; I=3.4 uA
19:24 BB HV S14 & S1 trip
19:30 Run L4443 and R20813 startED
19:32 S1-S7 & S14 all tripped; correlated with beam spike and failure
19:35 S14 tripped again during power up; same time as beam spike/trip
19:39 Run L4444 started
19:43 S5,S6, S14 trip when beam spiked/failed
19:47 Run L4445 started
19:52 S2,S3, S14 trip when beam spiked/failed. MCC crew chief said trips
are due to cavities dropping out. Before dropping out they go unstable
and spray the beam around, hitting the beam pipe ...
MCC will attempt to retune upstream in hopes of a more stable orbit
downstream in event of failure