User name a-onl
Log entry time 06:54:48 on May 25, 2008
Entry number 239575
keyword=End_of_Run_1550
****************************
Run Number: 1550
End of Run Comment:
Run_type=Production,target_type=Al Dummy,beam_e0=1.192,beam_raster=on,leftarm_p=0.6546,leftarm_theta=55,leftarm_colli=out,bbarm_i=700,bbarm_theta=35.0,bbarm_zoff=,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Production 20uA beam on 6cm Al target, kinematics 4, delta=2%
PRESCALE FACTORS:ps1=1500 ps2=16777215 ps3=500 ps4=5000 ps5=1 ps6=65535 ps7=65535 ps8=100
EVENTS : [0]: 84871 [+]: 41992 [-]: 41625
TIME : [0]: 18.844 mins [+]: 9.319 mins [-]: 9.317 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -5.41900 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 2.19% [+]: 1.91% [-]: 2.57%
TRIGGER RATES: PRES/REAL
T1[0] :12.0/17927.1 Hz T2[0] : 0.0/0.0 Hz T3[0] :15.2/7586.7 Hz T4[0] : 5.6/28217.5 Hz T5[0] :33.8/33.8 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/10.6 Hz T8[0] :10.2/1024.0 Hz
T1[+] :11.9/17849.7 Hz T2[+] : 0.0/0.0 Hz T3[+] :15.1/7554.1 Hz T4[+] : 5.6/28104.5 Hz T5[+] :33.8/33.8 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/10.8 Hz T8[+] :10.2/1024.0 Hz
T1[-] :11.9/17865.9 Hz T2[-] : 0.0/0.0 Hz T3[-] :15.1/7561.5 Hz T4[-] : 5.6/28131.8 Hz T5[-] :33.6/33.6 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/10.7 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 13512/20269041 T2[0] : 0/0 T3[0] : 17155/8577780 T4[0] : 6380/31903697 T5[0] : 38252/38252 T6[0] : 0/0 T7[0] : 0/12032 T8[0] : 11577/1157771
T1[+] : 6653/9980458 T2[+] : 0/0 T3[+] : 8447/4223755 T4[+] : 3142/15714274 T5[+] : 18896/18896 T6[+] : 0/0 T7[+] : 0/6013 T8[+] : 5725/572557
T1[-] : 6658/9987484 T2[-] : 0/0 T3[-] : 8454/4227097 T4[-] : 3145/15726446 T5[-] : 18793/18793 T6[-] : 0/0 T7[-] : 0/5957 T8[-] : 5724/572443
AVERAGE CURRENT
BCM x1 : 16.5920uA BCM x3 : 16.5901uA BCM x10: 8.3374 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -586.4 ppm BCM u3 : -555 ppm BCM u10: 1E+39 ppm
BCM d1 : -586.2 ppm BCM d3 : -546.3 ppm BCM d10: -548.5 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.01881 BCM u3 [0]:0.01881 BCM u10[0]:-2.098E-05
BCM u1 [+]:0.00926 BCM u3 [+]:0.00926 BCM u10[+]:-1.038E-05
BCM u1 [-]:0.009269 BCM u3 [-]:0.009268 BCM u10[-]:-1.038E-05
BCM d1 [0]:0.01871 BCM d3 [0]:0.01871 BCM d10[0]:0.01887
BCM d1 [+]:0.009214 BCM d3 [+]:0.009212 BCM d10[+]:0.009293
BCM d1 [-]:0.009223 BCM d3 [-]:0.00922 BCM d10[-]:0.009302
****************************
End-of-run EPICS data for Run Number 1550 at Sun May 25 06:54:39 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.654587
Left Arm arm angle : 54.9968
Right Arm D1 momentum : 0.00436268
Right Arm arm angle : 0.197
HALLA:p : 1192.16
HALLA:dpp : -0.000188413
Tiefenbach Hall A energy : 1192.16
Left Arm Top VDC Current : 5.17578
Left Arm Bottom VDC Current : 2.19727
-----
Left Arm Q1 momentum : 0.654581
Left Arm Q1 power supply : 492.462
Left Arm Q1 gauss meter : 0.04225
Left Arm Q2 gauss meter : -0.14864
Left Arm Q2 power supply current : 281.804
Left Arm Q2 momentum : 0.654444
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 217.427
Left Arm D1 momentum : 0.654587
Left Arm D1 NMR : 0.27566
Left Arm Q3 gauss meter : 0.133136
Left Arm Q3 power supply current : 260.635
Left Arm Q3 momentum : 0.654668
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00459173
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -0.0001066
Right Arm Q2 power supply current : -0.000292094
Right Arm Q2 momentum : -6.78709e-07
Right Arm Q2 gauss meter : -0.0003024
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0278101
Right Arm D1 momentum : 0.00434006
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 1.12089e-05
Right Arm Q3 momentum : 0.000196463
Right Arm Q3 gauss meter : -0.0002649
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.603
BigBite Gaussmeter readback : 0.562
-----
Average current of the two cavities : 0.0251621
Current on Unser monitor : 13.1869
Current on Upstream bcm : 0.0356232
Current on Downstream bcm : 0.014701
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.070854
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.16
Hall A momentum orbit correction (dpp) : -0.000188413
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.16
Hall C energy (hallc_MeV) : 5711.03
Delta(E)/E width (MV_AI_DXWID) : 1.46644
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.289062
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.334961
-----
Right Arm Collimator : -0.00834961
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 21.7773
HacR_HPE1313A:0_Ch54 : -0.849121
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 70
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.37764
SLI vert. size mm : 0
SLI y position : 3.31268
-----
Target : L3 6cm
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 1.37038e+07
Target type : 1.37038e+07
temperature loop 1(1) : 97.93
temperature loop 1(2) : 97.56
temperature loop 1(3) : 93.3
temperature loop 3(1) : 19.93
temperature loop 3(2) : 19.92
temperature loop 3(3) : 29.99
Heat exchange LH2 : 89.7
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.246356
HPH H2 loop 3 : 115.634
-----