• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name R. Michaels

    Log entry time 12:08:20 on September 03, 2008

    Entry number 242822

    keyword=L-HRS scalers ready (but waiting for target state)

    L-HRS scalers for normalization are ready, except for the gating
    signals which Kalyan will send me soon.

    They are run as 3800 mode. There are 5 scalers as we discussed:
    1) ungated, 2) gated by ++, 3) +-, 4) --, 5) -+
    where the two signs are for beam and target state.

    One problem: sometimes a scaler goes "bad". When it goes bad
    it reads back -1 for all channels. I've seen 2 diff scalers go bad
    like that, so far. The solution is to power cycle the crate.
    I don't know how often they go bad but this is a worrry.

    Bob

    A copy of this log entry has been emailed to: kalyan@jlab.org