Main INDEX
Monthly INDEX
PREV
NEXT
User name V. Sulkosky
Log entry time 10:55:42 on October 14, 2008
Entry number 243684
This entry is a followup to: 243677
keyword=Re: Second Target Spin State Electronics Working
I have added the second copy of the target spin signals to the ADC in
ROC 4 slot 21 channels 54 and 55. I removed the pedestal suppression for
these channels in ped4.dat for the a-onl account. I updated the
pedestal suppression code "ped_auto.f" so that ped suppression is
turned off for the target spin signals in ROC 4, slot 21,
channels 54 and 55.
The signals travel through patch panel ALFRED row D. Here is a complete
list of the channels:
Patch Panel ADC Channel Description
-----------------------------------------------
D1 48 Target Spin up
D2 49 Target Spin down
D3 50 MPS
D4 51 QRT
D5 52 Helicity Copy 1
D6 53 Helicity Copy 2
D7 54 Target Spin up 2
D8 55 Target Spin down 2
A copy of this log entry has been emailed to: kalyan@jlab.org,jinhuang@jlab.org,jiang@jlab.org