    User name Yi Qiang

    Log entry time 00:41:13 on November 06, 2008

    Entry number 247033

    keyword=Max Polarization for current Transverse and Vertical Pumping

    ============ Vertical Pumping ============

    Holding Field: Vertical + Pumping Direction: Parallel Ovent Temperature: 220 C Laser: FAPx4 100 W Target Location: Empty/Optics/Reference EPR Polarization/NMR = 52.2/31.9 = 1.64 Max Polarization = 35.6*1.64 = 58%

    ============ Transverse Pumping ============

    Holding Field: Transverse + Pumping Direction: Anti-Parallel Ovent Temperature: 220 C Laser: FAPx5 100 W Target Location: Empty/Optics/Reference EPR Polarization/NMR = 48.0/23.3 = 2.06 Max Polarization = 25.5*2.06 = 53%

    Current error on the max polarization is about +/- 2% absolute value

    A copy of this log entry has been emailed to: jpchen@jlab.org,jiang@jlab.org



    Vertical Spin UP



    Vertical EPR



    Vertical NMR after EPR



    Transverse Spin UP



    Transverse NMR after EPR