There was a successful NMR cross calibration. However, before next test, the correction coil current is not correctly setup. And polarization goes to low (~10%). So an spin up has been started for Spin Down. NMR Setting same as Spin Flip Time Interval = 120 min Oven = 230C Laser = 3 Comet Laser: 1.Rutgers@34A.20C 2.WM@35A.26C 3.JLab@36A.25C Start Point: Pick up Coil Pos Trans - Holding Field Spin Antiparallel to Field Pol.=~60% 11:06 NMR Freq Sweep -> Pol = ~60% (42mV) RTD#0->6=67C 133C 167C 106C 52C 223C 221C 11:20 Bigbite ->710A 11:51 Pumping Laser Off From now on there is no good NMR pol first guess since cell temperature changes 12:33 Temp Stable to Oven=330C Coil=-4.601A,6.232A,0.712A RTD#0->6=66C 134C 167C 107C 53C 224C 221C 12:40 Target -> He3 12:43 Freq NMR @ He3 -> Pol=~60% (40mV), Peak @ 81kHz 12:53 Temp Stable to Oven=330C Coil=-4.599A,6.230A,0.712A RTD#0->6=40C 71C 140C 61C 38C 223C 220C -------------------------------------------------------- NMR Cross Calibration Start -------------------------------------------------------- 12:54 Freq NMR @ He3 -> Pol=50-60% 33mV 01:00 Field -> Long + 01:02 Target -> Pick Coil 01:13 Temp Stable to RTD#0->6=64c 130c 167c 105c 52c 224C 221C 01:14 Field NMR @ Ref -> Pol=~56% (calib const changes when he3 temperature changes) 01:15 Target -> He3 01:27 Temp Stable to RTD#0->6=40C 71C 137C 62C 38C 223C 221C 01:27 Freq NMR @ He3 -> Pol=50-60% (31mV) -------------------------------------------------------- NMR Cross Calibration Ends -------------------------------------------------------- 01:50 Temperature change screen shot 02:06 NMR Field Sweep. Pol.=~40~50% 02:09 NMR AFP loss test with 2 field sweep -> AFP Loss =~ 0.7% 02:25 NMR AFP loss test with 5 Frequency sweep (Same Setting As Spin Flip) -> AFP Loss =~ 0.7% 2:38 Correction Coil On to Large = 5.00A Small = 5.00A 2:39 NMR AFP loss test with 2 Frequency sweep with Correction Coil ON -> AFP Loss = ~20%, -> Field Gradiant = Extream High, Peak Width is 5 time of normal 2:47 Correction Coil On to Large = 1.00A Small = 1.00A 2:47 NMR AFP loss test with 5 Frequency sweep with Correction Coil ON -> Field Gradiant = High, Peak Width is 1.5 time of normal -> AFP Loss = ~ 2.7% 2:58 Correction Coil On to Large = 0.50A Small = 0.50A 2:59 NMR AFP loss test with 5 Frequency sweep with Correction Coil ON -> AFP Loss = ~ 1.5% 3:10 Correction Coil OFF 3:12 NMR AFP loss test with 5 Frequency sweep with Correction Coil ON -> AFP Loss = ~ 1.0% -> Pol. = ~10% 3:30 Laser ON, Wait Temperature Stablized 3:47 Start Spin Up Spin Down. NMR Setting same as Spin Flip Time Interval = 120 min Oven = 230C Laser = 3 Comet Laser: 1.Rutgers@34A.20C 2.WM@35A.26C 3.JLab@36A.25C
Temperature change during cross calibration