    keyword=BB Cerenkov tests for tonight

    
    Here's some things we can do:
    
    20 minute runs, set prescales to obtain the usual rates as on the whiteboard.
    
    - On optics target:  0.1, 0.3, 0.5, 1 uA
    - On Reference cell w/ vacuum:  1 uA, 0.5uA(?)  
        - do raster check as usual for the glass cell
    - On 'No Target' position: 0.5uA, 1 uA
    
    A) Turn off all BB Cerenkov HVs _except_ the one for #19.
      i) Run 'threshold_BB -s BB_Cer -100' to set the T7 threshold.
        - Record the scalar rate on T7 once it stabilizes
        - Repeat (i) for BB_Cer thresholds of -300, -500, -700, -900mV
    B) Repeat (A), but turn off the HV for #19 and turn on PMT #20
    
    Please make a clear summary with the Run#, beam/target configuration, and
    measured rates from A, B and halog it.  Please take care that the entry
    doesn't get mangled by the halog software (ie. use the 'Preformatted