• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 06:27:25 on November 21, 2008

    Entry number 250144

    This entry is a followup to: 250090

    Followups:

    keyword=how to back out (RICH DAQ change)

    I''m not a RICH expert but I guess "something wrong" means not as many photons and
    worse signal/noise ratio ? Double check that this is really related to the DAQ change.

    If you are worried about the DAQ, two things can be tried to reverse the changes:
    1) Inrease the parameter for cramsWaitActive, put 500 back to 2000 or something in between.
    2) Return to previous CRL code version (it was saved, Alex knows ...).




    A copy of this log entry has been emailed to: ycwang@jlab.org,camsonne@jlab.org,cisbani@jlab.org