    User name R. Michaels

    Log entry time 00:46:55 on December 05, 2008

    Entry number 252087

    This entry is a followup to: 252070

    Followups:

    keyword=T3 -> T2 for now

    Pulser tests showed T3 input doesn't prescale correctly, apparently a hardware
    problem with the trigger supervisor.

    A workaround might be to use T2 input. (I'm a little nervous because the trig. super. might
    just be busted and needs to be swapped.) I suggested we run with T2 input for now and the
    RC agreed, but we may want to take stronger intervention tomorrow. (I mean we don't
    really know what's wrong with the TS, it might be a more insidious problem.)

    Kalyan has swapped T3 to the 2nd input, so it "appears" as T2 in the datastream and
    in scalers. This makes deadtime compute correctly. We'll run like this overnight.
    Kalyan will post more details momentarily. I think he's coming out of the hall soon.