User name R. Michaels
Log entry time 00:46:55 on December 05, 2008
Entry number 252087
This entry is a followup to: 252070
Followups:
keyword=T3 -> T2 for now
Pulser tests showed T3 input doesn't prescale correctly, apparently a hardware
problem with the trigger supervisor.
A workaround might be to use T2 input. (I'm a little nervous because the trig. super. might
just be busted and needs to be swapped.) I suggested we run with T2 input for now and the
RC agreed, but we may want to take stronger intervention tomorrow. (I mean we don't
really know what's wrong with the TS, it might be a more insidious problem.)
Kalyan has swapped T3 to the 2nd input, so it "appears" as T2 in the datastream and
in scalers. This makes deadtime compute correctly. We'll run like this overnight.
Kalyan will post more details momentarily. I think he's coming out of the hall soon.
(As for me, I'm at home in bed.)